오늘은 Brocade SAN switch 에서 지원하는 명령어에 대해 알아보겠습니다.
내용이 많은 관계로 우선 이번 글에서는 명령어 목록만 살펴보겠습니다.
해당 명령어 목록을 보기 위해서는 switch 접속하여 help 명령어를 사용하시면 됩니다.
aaaconfig ad ag agautomapbalance agshow aliadd alicreate alidelete aliremove alishow aptpolicy auditcfg auditdump authutil bannerset bannershow bcastshow bladecfggemode bladedisable bladeenable bladeswap bootluncfg bottleneckmon bpportloopbacktest bpturboramtest burninerrclear burninerrshow burninlevel burninstatus ceeportledtest ceeportloopbacktest ceeturboramtest cfgactvshow cfgadd cfgclear cfgcreate cfgdelete cfgdisable cfgenable cfgremove cfgsave cfgshow cfgsize cfgtransabort cfgtransshow chassisbeacon chassisdisable chassisdistribute chassisenable chassisname chassisshow classconfig clihistory cmsh configdefault configdownload configlist configremove configremoveall configshow configupload configure configurechassis cryptocfg datatypeshow date dbgshow defzone diagclearerror diagdisablepost diagenablepost diaghelp diagpost diagretry diagsetcycle diagshow diagstatus distribute dlsreset dlsset dlsshow dnsconfig enclosureshow errclear errdelimiterset errdump errfilterset errmoduleshow errshow fabportshow fabretryshow fabretrystats fabriclog fabricname fabricprincipal fabricshow fabstatsshow fabswitchshow fandisable fanenable fanshow fapwwn fastboot fastwritecfg fciphelp fcipledtest fcippathtest fcoe fcoelogincfg fcoelogingroup fcping fcplogclear fcplogdisable fcplogenable fcplogshow fcpprobeshow fcprlsprobe fcprlsshow fcrbcastconfig fcrconfigure fcredgeshow fcrfabricshow fcrlsan fcrlsancount fcrlsanmatrix fcrphydevshow fcrproxyconfig fcrproxydevshow fcrresourceshow fcrrouterportcost fcrrouteshow fcrxlateconfig fctraceroute fddcfg fdmicacheshow fdmishow ficoncfg ficonclear ficoncupset ficoncupshow ficonhelp ficonshow fipscfg firmwarecleaninstall firmwarecommit firmwaredownload firmwaredownloadstatus firmwarekeyshow firmwarerestore firmwareshow fmconfig fmmonitor fosconfig fosexec framelog framerpathtest fruinfoset fspfshow fwalarmsfilterset fwalarmsfiltershow fwclassinit fwconfigreload fwfrucfg fwhelp fwmailcfg fwportdetailshow fwsamshow fwset fwsettocustom fwsettodefault geporterrshow grep h hadisable hadump haenable hafailover hashow hasyncstart hasyncstop help historyclear historylastshow historymode historyshow i iclcfg iflshow ifmodeset ifmodeshow interfaceshow iodreset iodset iodshow ipaddrset ipaddrshow ipfilter ipsecconfig iscsihelp islshow killtelnet ldapcfg lfcfg licenseadd licenseidshow licenseport licenseremove licenseshow licenseslotcfg linkcost login logout lscfg lsdbshow mapsconfig mapsdb mapsgroup mapspolicy mapsrule mapssam memshow minispropshow more motd mscapabilityshow msconfigure msfr msplatshow msplatshowdbcb msplcleardb msplmgmtactivate msplmgmtdeactivate mstddisable mstdenable mstdreadconfig myid nbrstateshow nbrstatsclear netstat nodefind nsaliasshow nsallshow nscamshow nsdevlog nsshow nszonemember nszoneshow openfr opensource passwd passwdcfg pathbwconfig pathinfo pdshow perfaddeemonitor perfcfgclear perfcfgrestore perfcfgsave perfclearalpacrc perfcleareemonitor perfdeleemonitor perfhelp perfmonitorclear perfmonitorshow perfresourceshow perfsetporteemask perfshowalpacrc perfshoweemonitor perfshowporteemask perfttmon ping ping6 portaddress portalpashow portbeacon portbuffercalc portbuffershow portcamshow portcfg portcfgalpa portcfgautodisable portcfgcompress portcfgcreditrecovery portcfgdefault portcfgdport portcfgencrypt portcfgeport portcfgexport portcfgfaultdelay portcfgfec portcfgfillword portcfgfportbuffers portcfggemediatype portcfggport portcfgislmode portcfglongdistance portcfglosstov portcfglport portcfgnpivport portcfgnport portcfgoctetspeedcombo portcfgpersistentdisable portcfgpersistentenable portcfgqos portcfgshow portcfgspeed portcfgtrunkport portcfgvexport portcmd portdebug portdecom portdisable portdporttest portenable portenccompshow porterrshow portfencing portflagsshow portledtest portlogclear portlogconfigshow portlogdisable portlogdump portlogdumpport portlogenable portlogeventshow portloginshow portlogpdisc portlogreset portlogresize portlogshow portlogshowport portlogtypedisable portlogtypeenable portloopbacktest portmirror portname portperfshow portrouteshow portshow portstats64show portstatsclear portstatsshow portswap portswapdisable portswapenable portswapshow porttest porttestshow portthconfig porttrunkarea portzoneshow powerofflistset powerofflistshow psshow rasadmin rasman reboot roleconfig routehelp rtlogtrace saschiptest saspathtest secactivesize secauthsecret seccertutil secdefinesize secglobalshow sechelp secpolicyabort secpolicyactivate secpolicyadd secpolicycreate secpolicydelete secpolicydump secpolicyfcsmove secpolicyremove secpolicysave secpolicyshow secstatsreset secstatsshow sensorshow serdestunemode setdbg setverbose sfpshow shellflowcontroldisable shellflowcontrolenable sleep slotpoweroff slotpoweron slotshow snmpconfig snmptraps spinfab sshutil statsclear stopporttest supportffdc supportftp supportsave supportshow supportshowcfgdisable supportshowcfgenable supportshowcfgshow switchbeacon switchcfgpersistentdisable switchcfgpersistentenable switchcfgspeed switchcfgtrunk switchdisable switchenable switchname switchshow switchstatuspolicyset switchstatuspolicyshow switchstatusshow switchuptime switchviolation syslogdfacility syslogdipadd syslogdipremove syslogdipshow sysmonitor sysshutdown systemverification tempshow thconfig thmonitor timeout top topologyshow tracedump trackchangeshelp trackchangesset trackchangesshow trunkdebug trunkshow tsclockserver tstimezone turboramtest uptime urouteconfig urouteremove urouteshow usbstorage userconfig userrename version wwn wwnaddress zone zoneadd zonecreate zonedelete zonehelp zoneobjectcopy zoneobjectexpunge zoneobjectrename zoneobjectreplace zoneremove zoneshow |
Configure RADIUS for AAA services Specifies all administration domain (AD)-level operations Configure the Access Gateway feature Configure the Access Gateway automapbalance feature Displays the Access Gateway information registered with the fabric Add a member to a zone alias Create a zone alias Delete a zone alias Remove a member from a zone alias Print zone alias information Get and set Advanced Performance Tuning policy Modifies and displays audit log filter configuration. Display audit log Get and set authentication configuration Set security banner Display security banner Display broadcast routing information Configure 1GigE/10GigE port configuration for blade Disables all user ports on a blade. Enables all User Ports on a blade. Swaps area numbers for all ports on a blade Configure boot LUN for an HBA Configure port bottleneck monitor Functional test of port via blade processor path. MBIST test for AP blade BP ASICs Clear errors that are stored in the non-volatile storage Display errors that are stored in the non-volatile storage Set diagnostics level Display the diagnostics burnin status. Cycle user port LEDs. Functional test of port N->N path. MBIST test for ASICs Display Effective zone configuration information Add a member to a configuration Clear all zone configurations Create a zone configuration Delete a zone configuration Disable a zone configuration Enable a zone configuration Remove a member from a configuration Save zone configurations in flash Print zone configuration information Print size details of zone database Abort zone configuration transaction Print zone configurations in transaction buffer Set chassis beacon on or off Disable all ports in chassis Distributes data to physical chassis in a fabric Enable all ports in chassis Display or set the chassis's Name Display all Field Replaceable Units (FRU) Display RBAC class permissions Displays a log of most recently executed CLI commands Start CEE Management Shell Reset config to factory default Load switch config from a server List the stored config files Remove a stored config file Removes all configuration data from switch Print switch config parameters Save switch config to a server Set logical switch config parameters Set chassis config parameters Configure encryption node functions Display available diagnostic data types. Print/set the system date and time Display debug levels of various modules Activates or deactivates a default zone configuration. Clears diagnostics failure status. Disable diagnostic POST. Enable diagnostic POST. Display diagnostic command descriptions. Displays the contents of port registers and memories. Sets diagnostic retry mode Set diagnostic script parameters. Display diagnostic status. Display currently running diagnostic tests. Distributes data to switches in a fabric. Configure dynamic load sharing (DLS) option Configure dynamic load sharing (DLS) option Display the state of the dynamic load sharing option Configure DNS service Display the switch enclosure attributes Clear error log Sets the error log start and end delimiter for messages sent to the console and syslog Print error log (no page breaks) Sets a filter for an error log destination Displays all the defined modules in the system Print error log Display contents of a particular port's data Display retry count of various fabric commands Display retry count of fabric SW_ILS commands Displays or manipulates the fabric log Configure fabric name Configure Principal Switch Selection mode Print fabric membership info Displays the fabric statistics information Display fabric switch state information Disables a fan unit. Enables a fan unit. Print fan status Configure the Virtual PWWN for port Reboot this switch and bypass POST Configure FC fastwrite feature Print FCIP help info Cycle user port LEDs. Data Path Test of the FCIP complex. Displays and configures FCoE ports FIP and fcmap configurations Enable/Disable Save or display FCoE login configuration Creates or modifies FCoE login configuration Sends a FC ELS ECHO request to a port Clear the FCP log Disable logging of FCP events Enable logging of FCP events Display FCP probing log information Display FCP probing information Manage RLS probing Display FCP RLS (read link state) information Configure interfabric broadcast frame forwarding Sets FC Router configuration parameters. Displays FIDs assigned to defined EX_Port Displays FC Routers on a backbone fabric. Configure LSAN policies Display maximum LSAN zone limit. Manage LSAN fabric matrix configuration. Displays FC Router physical device information. Displays or configures proxy devices presented by an FC Router. Displays FC Router proxy device information. Displays FC Router physical resource usage. Modify FC Router port cost configuration. Displays FC Router route information. Displays or persistently configures a translate (xlate) domain's domain ID for both EX_Port-attached fabric and backbone fabric. Displays FC traceroute information fddcfg manages the fabric data distribution configuration parameters. Display abbreviated remote FDMI device information according to remote domain ID Display detailed FDMI device information Manage FICON configuration Clears contents of the specified FICON management database Sets FICON-CUP parameters for a switch Displays FICON-CUP parameters for a switch Displays FICON commands Displays contents of the specified FICON managementdatabase Configure FIPS mode operation Perform from scratch firmware install Commit firmware to stable storage Download firmware into switch Display the progress and status of firmwareDownload Manage the keys used to check firmware signatures Restore the old firmware in the switch Display firmware versions in the switch Configure Frame Monitors Configure Frame Monitors Enable/disable FabOS services Invoke command in alternate VF context Configure logging of discarded frames Tests data path between ASICs sets data in FRU Header Print FSPF global information Configure alarms filtering for Fabric Watch Show alarms filtering for Fabric Watch Initialize all Fabric Watch classes Reload Fabric Watch configuration Configure FRU state and notification Print Fabric Watch help info Configure Fabric Watch Email Alert Create a report with detailed port information Show availability monitor information Set port persistence time Set boundary & alarm level to custom Set boundary & alarm level to default Print GigE port error summary Linux grep command Print shell history Disables the High Availability feature in the switch. Displays information about the status of the High Availability feature in the switch. Enables the High Availability feature in the switch Forces the failover mechanism so that the Standby Control Processor (CP)becomes the Active CP. Displays control processor (CP) status Enables HA state synchronization. Disables the HA state synchronization. Print this list Clears the Field Replaceable Unit (FRU) history log Displays last history record Display or set the mode of the history log Displays entire history log Display process summary Configure ICL state Display edge switch FCR connection information Set the link operating mode for a network interface Display the link operating mode for a network interface Display the FSPF (TM) interface information Turn off the in-order delivery (IOD) option Manage the in-order delivery (IOD) option Display the state of the in-order delivery option Set ethernet and FC IP addresses Print ethernet and FC IP addresses Manage/display IP filters Configure IPSec feature Print iSCSI help info Display the current connections and status Terminate telnet/serial login sessions interactively Configure LDAP role mapping Configure logical fabrics Adds license keys to switch Displays the system license ID Configure per-port POD license assignments Removes a license key from this system Displays current license keys Configure licenses on a slot basis Set or print the FSPF cost of a link Login as a new user Logout from remote session Configure logical switches Displays the FSPF link state database Configure MAPS features Configure MAPS features Configure MAPS features Configure MAPS features Configure MAPS features Display port times Display memory usage in the system. Displays ASIC pair properties. Linux more command Set chassis login banner Display Management Server Capability. Configure Management Server Create a MSFR Zone Display the Management Server Platform Database Display the Management Server Database Control Block Clear the Management Server Platform Database fabric-wide Activate the Management Server Platform Database fabric-wide Deactivate the Management Server Platform Database fabric-wide Disables the Management Server Topology Discovery Management Service Enables the Management Server Topology Discovery Management Service Display status of Management Server Topology Discovery Service Display the current login session details Display FSPF (TM) neighbors' states Reset the FSPF (TM) interface counters Display network connections and statistics Display all the devices' PID matching the given world wide name Display local Name Server information with Aliases Print global Name Server information Print local Name Server Cache information Manage Name Server device logs Print local Name Server information information Display the information of all the online devices which are zoned with the given device. Display zone names of specific zoned devices Create a MSFR Zone Display information on open source software utilized in FabOS Set usernames and passwords passwdcfg manages the password policies. Manage ISL and ICL bandwidth features Display routing information between two ports Show information from Panic Dump file Add end-to-end monitor Clear Performance settings from FLASH Restore Performance configuration from FLASH Save Performance configuration to FLASH Clears the CRC error count associated with a port and Arbitrated Loop Physical Address (AL_PA). Clears statistics counters of one or more end-to-end performance monitors. Delete end-to-end monitor Print Performance Monitoring help info Clear end-to-end/filter-based/ISL monitors Show end-to-end/filter-based/ISL monitors Show monitor availability Set overall mask for end-to-end monitors Get ALPA CRC count by port and ALPA Show user-defined end-to-end monitors Show the current end-to-end mask Configure bandwidth usage monitor Display the link operating mode for a network interface Display the link operating mode for a network interface Configure low 16 bits of Fibre Channel Porrt ID Show the ALPAs of a port Enable or disable port beacon Compute port buffer requirements Print the buffer allocations for the ports of a quad Display filter utilization Create/Delete a new ip interface/route/arp entry onthe GigE port Set AL_PA to 0x0 (default) or 0x13 Configure auto disable Configure in-flight data compression Configure credit recovery Restore the port configuration to defaults Configure Diagnostic port function Configure in-flight data encryption Enable/Disable a port from becoming E_Port Sets a port to be an EX_Port and sets and displays EX_Port configuration parameters. Configure fault delay for a port Configure Forward Error Correction feature Configure a port to a particular fill word Configure F_Port buffers Configure media type for GigE port Lock a port as a G_Port Configure a port to be ISL R_RDY Mode enabled/disabled Configure a Long Distance Port Configure frontend port signal debounce Lock a port as a L_Port Configure NPIV functionality on a port. Enable/disable N_Port capability for a port Set port speed combination for port octet Persistently disable a port Enable a persistently disabled port Configure QoS feature Displays port configuration settings. Configure a port to a particular speed level Configure a port for trunking Sets a port to be an VEX_Port connected to FC-IP and sets and displays VEX_Port configuration parameters. Execute commands (ping etc) on the GigE port Set debug level and verbosity level of port modules Disable E_Port in trunk group Disable a specified port Enable Diagnostic port test Enable a specified port Print the encryption and compression configurations for the ports of a chip present in the switch. Print port error summary Configure Fabric Watch port fencing feature Display the port status bitmaps of all ports in a switch Cycle user port LEDs. Clear port activity log Display portlog configuration Disable portlog facility Print port log (no page breaks) Print port log (no page breaks) Enables port log facility Display information about port log events Display port login information Set or clear the debug_pdisc_flag Enable portlog facility Resize the port log Print port activity log Print port activity log Disable port logging Enable port logging Functional test of port N->N path. Manage port mirroring configuration Assign or display the name associated with a port Print port throughput numbers Display various routing tables for a port Show configured ip interfaces/routes/arp entries on the GigE Port Display the 64-bit hardware statistics for a port Clear the status of a specified switch port Print hardware statistics Swaps area numbers Disable portswap feature Enable portswap feature Display port and area information Functional test on a live fabric. Starts porttest. Retreive information from porttest. Configure Fabric Watch port threshold monitor Configure area trunking Displays the enforced zone type of the F/FL-ports of a switch. sets slot power off list order Displays slot power-off order. Print power supply status Manage RAS log filters Display RAS message description Reboot this processor Manage user-defined RBAC roles Print routing help info Configure logging facility for asynchronous dual CP conditions Functional Test of Components in SAS Complex. Data Path Test of the SAS complex. Displays size of the active (security) database Creates/Manages DHCHAP secret key details Creates/Manages/Displays third party PKI certificates Displays size of the defined (security) database Displays current internal security state information Displays information about security commands Aborts changes to defined policy Activates all policy sets Adds members to an existing policy Creates a new policy Deletes an existing policy Displays all members of existing policies Moves a member in the FCS policy Removes members from an existing policy Saves defined policy set and sends to all switches Shows members of one or more policies Resets security statistics Displays security statistics Display sensor readings Configure serdes tuning mode Set debug level of the specified module Set verbosity level of the specified module Print Serial ID SFP information Disable xon-xoff flow control on console serial port Enable xon-xoff flow control on console serial port Linux sleep command Removes power from a slot. Restores power to a slot. Displays the status of all slots in the system. Configure SNMP Configure SNMP traps Functional test of switch to switch ISL cabling and trunk group operation. Configure SSH authentication options Clear port and diagnostic statistics. Terminate the running porttest. Modifies or displays first-failure data capture(FFDC) configuration. set support Ftp parameters retrieve support data from switch to host Prints switch information for debugging purposes. Disables a group of commands under supportshow command. Enables a group of commands under supportshow command. Displays the groups of commands enabled for display. by the supportshow command. Set switch beacon on or off Persistently disable a switch Enable a persistently disabled switch Configures all ports of the switch to a particular speed level Configure all ports on the switch for trunking Disable this switch Enable this switch Print/set this switch's name Print switch and port status Set policy parameters for overall switch status Print policy parameters for overall switch status Print overall switch status Display the amount of time for which the switch is up Display policy violations recorded in RAS log Change the syslog facility Add syslog daemon IP address Remove syslog daemon IP address Print the syslog daemon targets Configure system memory usage monitor Provides a graceful shutdown to protect the switch file systems. Run a suit of diagnostic tests on all switches in a system. Print temperature readings Configure Fabric Watch thresholds Configure Fabric Watch threshold monitors Set/show the IDLE timeout value for a login session Linux top command Display the unicast fabric topology generate/remove trace dump or display trace dump status Print Track Changes help info Configure alert for login/logout/config update Displays status of track changes Debug a trunk link failure Display trunking information Displays or sets the NTP server address Displays or sets the time zone Turbo SRAM test for bloom ASICs. Print how long switch has been up Configure a static route Remove a static route Display unicast routing information Manage USB storage device (available on Brocade Data Center Director only). Display or configure user accounts Rename user login name Print firmware version Display or set the world wide name Configure persistent PID assignments Configure zone objects Add a member to a zone Create a zone Delete a zone Print zoning help info Copies a zone object Expunges a zone object Rename a zoning Object Replace a zoning Object Remove a member from a zone Print zone information |
이상 Brocade SAN switch 명령어 list였습니다.
누군가에게 도움이 되기를..
'UNIX&LINUX > AIX Server ADMIN' 카테고리의 다른 글
AIX 화면 갈무리 (0) | 2014.08.28 |
---|---|
Firefox에서 HMC 접속하여 open terminal 수행시 에러 발생 (0) | 2014.08.28 |
윈도우7 텔넷 사용하기 (0) | 2014.08.28 |
Tape Drive 관리하기 (0) | 2014.08.28 |
[AIX BASIC] File, Directory 관리와 Tip (0) | 2014.08.28 |
[AIX Basic] AIX 소개 (0) | 2014.08.28 |
[FTP] 기본 사용법 (0) | 2014.08.28 |
[AIX 파헤치기] user 와 group 관리하기 (0) | 2014.08.28 |